The Sullivan

 

cladding reinstatement to replace all combustible aluminium composite panels

LocationClient
Canberra, ACT
Australia
JW Land
ScopeStatus
FP 1.4 Weatherproofing | Condensation Assessments | Internal and External Waterproofing | Engineering Site Support |
Testing & Commissioning
Ongoing

With a stance such as ‘Sustainably Stylish’, The Sullivan aligns perfectly with Canberra’s vision of creating communities that are kinder to its environment and in combination with using superior quality materials. We are excited to be part of such a pioneering project for the ACT region.

Freezing outside temperatures during winter in Canberra, inevitably have people resort to warm, conditioned air inside the building. When warm, humid air meets a relatively cold surface and the air cools down below its dew point, the warm air condensates and water droplets form on the cold surface. The excessive moisture leads to health risks, stains and swelling of materials, structural decay and a reduction in a structure’s energy efficiency, which in turn causes loss of thermal performance due to dampness present in the insulation.

In order to control the physics of heat, cold and moisture, interstitial and surface condensation assessments were carried out using FEM to inform the design team on condensation and mitigation scenarios.

JFS has been appointed to conduct weatherproofing FP1.4, condensation, and waterproofing assessments on The Sullivan.

cladding reinstatement to replace all combustible aluminium composite panels

LocationClient
Canberra, ACT
Australia
JW Land
ScopeStatus
FP 1.4 Weatherproofing | Condensation Assessments | Internal and External Waterproofing | Engineering Site Support |
Testing & Commissioning
Ongoing

With a stance such as ‘Sustainably Stylish’, The Sullivan aligns perfectly with Canberra’s vision of creating communities that are kinder to its environment and in combination with using superior quality materials. We are excited to be part of such a pioneering project for the ACT region.

Freezing outside temperatures during winter in Canberra, inevitably have people resort to warm, conditioned air inside the building. When warm, humid air meets a relatively cold surface and the air cools down below its dew point, the warm air condensates and water droplets form on the cold surface. The excessive moisture leads to health risks, stains and swelling of materials, structural decay and a reduction in a structure’s energy efficiency, which in turn causes loss of thermal performance due to dampness present in the insulation.

In order to control the physics of heat, cold and moisture, interstitial and surface condensation assessments were carried out using FEM to inform the design team on condensation and mitigation scenarios.

JFS has been appointed to conduct weatherproofing FP1.4, condensation, and waterproofing assessments on The Sullivan.